HOME List of All Products, Details and Descriptions Photos and Forms Brochures, Drawings and Instructions Address, Phone or Email Cant find it? Look here... Products YOU can use
BH Series -   Installation Instructions
 
Mounting on Rectangular Hoppers (Flat surface)
Determine proper mounting location, assure a mounting angle greater than 20 degrees unless 'SP' type. (Spring Option)

A backing plate is recommended to reinforce the bin wall (normally the same thickness as the bin wall)

Weld plate 'A' part number  to hopper wall or backing plate (skip weld and avoid weld in corners) with low hydrogen rod.

Insert bolts 'B' in slots and place vibrator over bolts
Install and thread lockwasher and nut 'D'. Tighten securely.

Install a safety cable (part number CB 0.00) from the eye of the vibrator to a permanent structure nearby. 

Following air supply connection, operate vibrator for a short time and retighten all fasteners.


 
 
Mounting on Conical Hoppers (Curved Surface) Channel Mounting Plate
Determine proper mounting location. Assure a mounting angle greater than 20 degrees unless 'SP' type.

A backing plate is recommended to reinforce the bin wall (usually the same thickness as the bin wall)

Install mounting bolts 'B' through holes in mounting channel 'A' (part number)

Weld both channel legs to hopper wall or backing plate (skip weld and avoid ends) with low hydrogen rod.

Install and thread lockwashers and nuts 'D' tighten securely.

Install a safety cable (part number CB 0.00) from the eye of the vibrator to a permanent structure nearby. 

Following air supply connection, operate vibrator for a short period and retighten all fasteners.


 
 
Air Control Connections
Install air control package (part number)

Fill the lubricator with SAE 10 or lighter non-detergent oil.

Set pressure regulator to 50 p.s.i.

Open Valve

Adjust the lubricator to approximately 10 drops of oil per minute.

Operate vibrator for five minutes

Inspect and re-tighten all mounting fasteners and air line connections.

Adjust air regulator for the lowest pressure which will give the the desired material flow performance. Not to exceed 60 psi.

Periodically fill oil reservoir to assure lubrication for the vibrator.

All vibrators must be installed with an inline lubricator, filter and regulator.